That will be the size of your circuit and breaker.
32 amp plug cable size.
The minimum wire size for 30a is 10 awg.
Wire gauge refers the physical size of the wire rated with a numerical designation that runs opposite to the diameter of the conductors in other words the smaller the wire gauge number the larger the wire diameter.
Now size your breaker and wires.
They draw 40 amps 14 amps and 3 amps respectively.
So 37 5 becomes 40.
The wire size calculator will give you a very simple and quick solution to the problem of calculating the size of wires and cables for pump applications in golf courses landscape projects and agriculture.
On 32 amp installations the cable running from the main power supply to the isolator plus from the isolator to the hot tub are both required.
40 x 1 25 14 3 50.
In most instances the size of cable should be printed on the sheath but if not you will need to calculate the diameter of the wire to determine its size which means working out the area of a circle e.
Common sizes include 14 12 10 8 6 and 2 gauge wire.
There is no 40 amp outlet made so using a 50 amp outlet appears acceptable in this one narrow case.
Code appears to allow a 40 amp breaker and circuit for a 50 amp nema 14 50 outlet for one very specific case a range or oven that is always left plugged in.
On 13 amp we expect a water proof socket to be situated at 2 5 metres from the hot tub.
16a plug 13a socket 13a plug 16a socket 16a plug 16a socket 16a plug 32a socekt for a 10m lead 4 0mm will be ok for 32a plug 32a socket for the 32a plug 16a socket you will need to run a length of 4mm from the 32a plug into a 2 module high impact enclosure and fit a single 16a mcb in there then run from that in 2 5mm to the 16a socket.
Wire is sized by the american wire gauge awg system.
The minimum wire size for 40a is 8 awg.
The figure we would plug into the calculator would be.
Special case 50 amp outlet on a 40 amp breaker.
Enter your proposed cable size type of insulation voltage ambient temp 30 is norm your cable length and circuit load in amps.
Take your instructions or derated amps number and round up to the next larger size of 30 40 or 50.
To ensure the power the power cable is ready for the engineer to connect to the hot tub.
The minimum wire size for 50a is 6 awg copper or 4 awg aluminum.
Cable selection copper only up to 25mm above this cable reactance must be considered.
As we have established above how you identify electrical cable size is through the size of wire it houses e g 1 5mm cable houses 1 5mm wire.